Guardrails: the right height, secure fixing and technical requirements

Guest: Joeri Luckermans | Host: Björn Crul
When is a guardrail required? How high should it be, and what technical and safety requirements must it meet? In this episode of the Buildwise podcast, Björn Crul is joined by Joeri Luckermans, technical adviser at Buildwise, to discuss the rules and key considerations when designing, installing and inspecting guardrails.
They discuss the applicable standards, the correct protective height, permitted openings and requirements for glass guardrails. They also cover anchoring guardrails to façades, installing them on flat roofs without compromising waterproofing, and the specific requirements for stairs and landings. Finally, Joeri explains which technical publications and practical tools Buildwise provides for construction professionals.
Full transcript
Alle hoofdstukken (19)
- Introduction: guardrails and the Buildwise campaign
- Why launch a campaign on guardrails?
- When is a guardrail required?
- Standards for guardrails and external joinery
- Lockable windows and opening restrictors
- Minimum protective height and the correct way to measure
- Common measurement errors and standing zones
- How renovation work affects protective height
- Guardrail geometry and permitted openings
- Aesthetic preferences and safety requirements
- Strength, stability and testing of guardrails
- Buildwise's technical information note and practical guide
- The composition and safety of glass guardrails
- Damage, discolouration and delamination in glass guardrails
- Fixing and anchoring guardrails
- Guardrails on flat roofs and the watertightness of the roof waterproofing
- Specific rules for stairs and landings
- Buildwise publications and technical information
- Closing the podcast
Introduction: guardrails and the Buildwise campaign
Björn Crul Hello, listeners, and welcome to this new podcast in partnership with Buildwise. I’m Björn Crul, and today we’re discussing a topic that may sound less exciting than BIM or sustainability, but that every contractor, architect and joiner encounters every week: guardrails. When is your window sufficient as fall protection, and when isn’t it? What is the correct height for a guardrail? How do you fix one to a flat roof without damaging the roof waterproofing? And which technical requirements do you need to take into account? Buildwise, the innovation and research centre for the construction sector, is launching a campaign this year specifically focused on guardrails. And that’s no coincidence. The regulations are being revised and new technical requirements are being introduced. My guest today is Joeri Luckermans from Buildwise, who contributed to Buildwise’s new guide to guardrails. Welcome to our studio.
Joeri Luckermans Thank you, Björn.
Why launch a campaign on guardrails?
Björn Crul Every year, Buildwise brings a number of topics to the attention of stakeholders in the construction sector. This year, guardrails are one of them. What prompted you to put this topic on the agenda now?
Joeri Luckermans The reason is mainly practical. Guardrails may seem like a simple building element at first glance, but our Technical Business Services department receives a lot of questions about them. When exactly do you need fall protection? How high does it have to be? From where do you measure the height? How do you demonstrate that the guardrail is strong enough? In addition, the NBN B 03-004 standard has been revised, so this is a good time to bring the rules together again in a clear, practical way for designers and contractors.
Read the full transcriptCollapse transcript17 more chapters
When is a guardrail required?
Björn Crul Yes, let’s start at the beginning. If a window extends down to floor level or there is a low sill, when is a guardrail actually required?
Joeri Luckermans The basic rule is quite simple. As soon as there is a level difference of 1 metre or more between the finished floor and the ground below, or, for example, a roof or another accessible surface, the risk of falling through must be reduced. That doesn’t automatically mean a separate guardrail always has to be installed. The external joinery itself can function as fall protection, but it must meet requirements including those for protective height, impact resistance and glazing. If it does not, an additional guardrail is required.
Standards for guardrails and external joinery
Björn Crul There are actually two standards in play specifically for guardrails: the standard for guardrails in buildings and the joinery standard, NBN B 25-002-1. Can you explain when these standards apply and what the difference is?
Joeri Luckermans You can look at it this way. NBN B 25-002-1 deals with external joinery. If a window or fixed glazed element itself provides fall protection, that’s the first standard we look at. It sets the requirements for protective height and impact resistance, as well as the choice of suitable glazing. If the joinery cannot provide that protection on its own, a separate guardrail is needed. In that case, we turn to NBN B 03-004. This standard sets out, among other things, the height, geometry, loads and tests that the guardrail must withstand.
Lockable windows and opening restrictors
Björn Crul We’re talking about guardrails, but there’s still an exception. Sometimes a window with a lockable handle or an opening restrictor is sufficient. When is that allowed, and what should you look out for?
Joeri Luckermans That is indeed possible, but there are clear conditions attached to this solution. In certain situations, an opening window can be considered a non-opening element if it remains locked during normal use with a key, or if it has an opening restrictor. In principle, the key may only be available to those responsible for maintaining the window, who may then open it. However, they must use the appropriate personal protective equipment during maintenance. The requirements for impact resistance and glazing also still apply. We would generally advise against this solution in a family home, because it makes safety heavily dependent on the key or restrictor being used correctly.
Björn Crul And where can it be used?
Joeri Luckermans It can be used, for example, in office buildings, offices and residential care centres where there is a clear separation between the maintenance team and the building’s end users.
Minimum protective height and the correct way to measure
Björn Crul If a guardrail is required, the right height obviously needs to be determined. In practice, the answer is sometimes less straightforward than people think. What are the basic rules?
Joeri Luckermans For a separate, thin guardrail, 1.10 metres is the usual minimum height. From a fall height of 12 metres, this increases to 1.20 metres. But this is where the nuances begin. For thicker guardrails or certain projecting elements, the required height may be assessed differently. These projecting elements make it more difficult to lean over or hang over the guardrail and fall from a height. But it is also essential to check the level from which someone can actually stand, sit or kneel. So the measurement from the floor does not tell the whole story.
Björn Crul And the question, of course, is how do you measure the protective height? Do you have a practical example?
Joeri Luckermans In a straightforward situation, you measure vertically from the finished floor someone is standing on to the top of the guardrail or handrail. Say you’re standing on a balcony with a thin guardrail and the fall height is less than 12 metres. In that case, you should aim for at least 1.10 metres from the finished floor. But if there is, for example, a wide, low upstand right next to the guardrail that someone could stand on, that upstand may become a new reference level. The protective height must then be assessed from that higher level.
Common measurement errors and standing zones
Björn Crul It’s not an easy subject. What are the most common mistakes you see on site, or when people determine and check the protective height?
Joeri Luckermans The most common mistake is simply to measure from the floor to the top of the guardrail and say: ‘Right, we’ve got 1.10 metres, so it’s fine.’ The standard also takes account of what are known as standing zones. That’s a technical term for surfaces someone can stand on, but which can also be used as a step. The standard assumes that elements up to 45 centimetres above finished floor level can, in principle, be used as a step. Think, for example, of a wide windowsill, a radiator cover or another upstand. From a width of 300 mm, the standard assumes that someone can stand on it securely. But narrower surfaces can also be relevant if, for instance, someone can stand on them with some support, while still being in an unstable position. So it’s important to look not only at the floor, but also at elements near the guardrail. Surfaces suitable for sitting or kneeling that are between 45 and 60 centimetres high can also affect the required height. The design must therefore be considered as a whole, not just the guardrail itself.
How renovation work affects protective height
Björn Crul Joeri, let’s look specifically at renovation work. I assume it can sometimes create a new risk. A new floor finish or raising the floor level can reduce the effective protective height of an existing guardrail. What should you do in that case?
Joeri Luckermans For renovation work, we certainly recommend checking the protective height again against the current standard, especially when the work has a significant impact on the existing situation. For example, if you raise a terrace or install a new floor finish over the existing one, the effective protective height is reduced. A guardrail that was high enough before the work may therefore no longer meet current safety criteria after the renovation. In that case, you should check whether the guardrail needs to be adapted or additional fall protection is required.
Guardrail geometry and permitted openings
Björn Crul Let’s look at the technical requirements. A guardrail must be high enough, but there are a number of other factors to consider, such as mesh size or the spacing between bars. What are the basic rules?
Joeri Luckermans The geometry is mainly designed to prevent two things: someone falling through the guardrail and the lower section being easy to climb. For that reason, openings are strictly limited up to 45 centimetres above the relevant standing zone. With vertical bars, the clear opening must be no more than 110 mm. These dimensions are also designed to prevent a child from putting their head through and then getting trapped. Above that zone, openings of up to 180 mm are permitted.
Björn Crul And what about horizontal or sloping elements?
Joeri Luckermans Stricter rules apply to horizontal or sloping elements because they can function like a ladder. For other infill types, the standard uses what it calls a gauge, which you can use to check that the opening is not too large. So there isn’t one universal mesh size. The permitted opening depends on the shape and position of the infill.
Aesthetic preferences and safety requirements
Björn Crul At Buildwise, you’ve found that an architect’s or client’s preferences can sometimes clash with safety requirements. Can you give an example? And how can an architect help reconcile appearance with protection?
Joeri Luckermans A classic example is the desire to make a guardrail as open and minimalist as possible, for instance using horizontal cables or large openings. Visually, this can be very attractive, but in the bottom 45 centimetres the standard is specifically intended to prevent the infill from being easy to climb or a body part from passing through an opening that is too large. Architects do have some scope for manoeuvre. You can use vertical elements, glass, closer-spaced infill in the bottom zone, or a design in which the open sections start higher up. It is worth taking the safety rules into account early in the design process. That usually makes it possible to arrive at an aesthetically pleasing solution without having to add a makeshift fix later.
Strength, stability and testing of guardrails
Björn Crul Once the guardrail has been designed, it obviously also has to be shown to comply. How can this be done? What methods are used?
Joeri Luckermans The standard considers both strength and stability, and behaviour under normal use. In calculation terms, we refer to the ultimate limit state, where the aim is to prevent failure or loss of equilibrium, and the serviceability limit state, where deformation must be kept within limits. In many cases, compliance can be demonstrated by calculation. If a system is difficult to calculate, testing may be necessary. There is also a dynamic check, known as the soft body impact test or pendulum test. A 50-kilogram impactor is raised and then swung against the guardrail. It is important to make sure that the most unfavourable points on the guardrail are tested. These might be the centre of an infill panel, at a post or close to a connection. In the case of a glass guardrail clamped only at the bottom, for example, an upper corner may be the most critical point, so it must also be tested there. The testing checks not only whether the guardrail can withstand an impact, but also its most vulnerable points.
Buildwise's technical information note and practical guide
Björn Crul As we mentioned, there is a new technical information note that also gives contractors and joiners practical help with the calculations. What exactly have you developed?
Joeri Luckermans Our main aim is to bridge the gap between the rather abstract requirements in the standard and the questions that arise in a specific design. The standard sets out the applicable loads and criteria. The technical information note helps make those principles practical and explains which components actually need to be sized: not just the posts or the glass, but also the fixings. Testing remains an option for systems that are not straightforward to calculate. The practical guide accompanying this campaign brings together the most common questions, so you can quickly see what to watch out for in the design.
The composition and safety of glass guardrails
Björn Crul Glass guardrails have been popular with architects and clients for some time, but of course not every type of glass is suitable for use as a guardrail. What are the requirements? How should the glass be made up?
Joeri Luckermans When the glass itself forms part of the fall protection, laminated safety glass is essential. It consists of at least two panes of glass bonded together with one or more interlayers. If the glass breaks, the fragments remain attached to the interlayer, so the glass does not simply fall away completely. This is important because the guardrail must still provide a degree of protection against falling through after the glass has broken. The standard specifies a particular safety class for this, known as the 1B1 classification. The exact thickness of the glass panes and the interlayers required cannot be specified in general terms. These depend, among other things, on the dimensions, how the glass is fixed and the loads on the guardrail.
Björn Crul Yes, for example, in the case of point fixings.
Joeri Luckermans Yes, with point fixings or higher loads, it may be necessary to use laminated safety glass with individual panes that are thermally toughened or heat-strengthened. The glass always remains laminated. Heat treatment makes the panes stronger, but it does not replace the laminated construction. That distinction is important. Stronger glass is not automatically safer. When a toughened glass pane breaks, it loses its load-bearing capacity very quickly.
Damage, discolouration and delamination in glass guardrails
Björn Crul Guardrails are also exposed to the elements, of course. Over time, damage, discolouration and delamination can occur. What are the most common problems, and when should a glass guardrail be replaced?
Joeri Luckermans With glass guardrails, we see more scratches, edge damage and optical effects, white discolouration at the edge and delamination. Not every visible effect automatically means that the glass is unsafe or needs replacing. Slight whitish discolouration extending up to around 25 mm from the edge is generally accepted. The widely used PVB interlayer is somewhat sensitive to moisture. It can therefore be a good idea to protect the top edge of the glass with a continuous top profile or handrail. This reduces the chance of moisture reaching the interlayer via the glass edge and damaging it.
Björn Crul And what degree of delamination is acceptable?
Joeri Luckermans Delamination limited to 15 mm is considered acceptable, although its progression should be monitored. The situation is different if the damage continues to develop, exceeds the tolerances or affects the glass's structural performance and residual protection. In that case, the cause must be investigated and replacement may be necessary. In other words, the first step is to establish whether it is a cosmetic issue or one that also compromises the safety function.
Fixing and anchoring guardrails
Björn Crul We should also discuss the points to consider when fixing a guardrail. It can be perfectly sized and still be unsafe if it is not properly fixed. Where can problems arise?
Joeri Luckermans The fixing is the final link in the load path, but a crucial one. A perfectly designed guardrail is no use if the forces are not safely transferred into a load-bearing part of the building. Problems can arise, for example, if anchors are placed too close to the edge of a concrete balcony, if they are fixed into a non-load-bearing outer leaf of the façade, or if the substrate is not sufficiently well understood. The guardrail must therefore be considered as a complete system: the infill, the posts, the connections, the anchors and the building substrate.
Björn Crul And how do you deal with this in a cavity wall or when fixing to the external joinery?
Joeri Luckermans In a cavity wall, the forces must be transferred to the load-bearing inner leaf or another structural element. You must not simply anchor the guardrail into the facing brickwork. Even where such a fixing initially seems strong enough, our long-term experience shows that it is not a reliable solution. NBN B 03-004 also does not permit this type of anchoring. With an ETICS façade, special mounting elements are required, which can be anchored sufficiently deep into the load-bearing substrate. Another option is to fix the guardrail to the external joinery itself. In that case, it is fixed to the fixed window frame and the system must be properly designed or tested. In practice, this is often done using a solution developed by the joinery system manufacturers, for example, with additional reinforcement in the PVC profiles.
Guardrails on flat roofs and the watertightness of the roof waterproofing
Björn Crul There are several points to consider with a guardrail on a flat roof. It needs to be securely anchored, while the roof waterproofing must of course remain watertight. How can this be achieved?
Joeri Luckermans You do indeed have to meet two requirements at once. The guardrail must be structurally sound and the roof waterproofing must remain watertight. The best solution is therefore a detail that avoids having to penetrate the roof waterproofing, for example, a structure stabilised by counterweights. If that is not possible, we prefer fixing to the outside face or making a penetration in the vertical surface above the roof upstand. A horizontal penetration through the waterproofing is more difficult to make durably watertight. The roof waterproofing upstand must also remain high enough. Generally, 15 cm above the roof surface is sufficient. For a terrace finish with open joints, such as tiles on adjustable supports, a specific requirement applies: the upstand must remain at least 5 centimetres above the finished floor. Thermal continuity and any drainage in hollow posts must also be considered. There is no need to start from scratch every time. The Buildwise detail database contains practical construction details showing how to execute this type of junction.
Specific rules for stairs and landings
Björn Crul We should of course also cover stairs and landings. Stairs are subject to specific rules that differ from the general guardrail standard. What are the main differences?
Joeri Luckermans On a staircase, the protective height is measured differently from on a horizontal floor. It is measured vertically from the nosing of the tread to the top of the handrail, and the minimum height is 900 mm. On the landing, the general rules apply again. For a thin guardrail, the usual heights are 1.10 metres and 1.20 metres when the fall height exceeds 12 metres. The rules for openings also differ on stairs, because they follow the geometry of the slope.
Björn Crul And what should you pay particular attention to on stairs and landings?
Joeri Luckermans A few points stand out. The gap between vertical elements of a stair guardrail must not exceed 110 mm. Between elements running parallel to the slope of the stairs, the limit is 180 mm. On a staircase without a string, the gap between the tread nosing and the bottom rail must not exceed 50 mm. On the landing, the guardrail continuing from the stair handrail must once again comply with the general rules for height and openings. The transition of the handrail between the stairs and landing also needs attention, to avoid creating unusual gaps or other openings.
Buildwise publications and technical information
Björn Crul Joeri, thank you for guiding us through the world of guardrails and setting out the various points to consider. Now, if any listeners would like more information, where can they find it?
Joeri Luckermans If you’d like to find out more, the first place to look is our new technical information sheet on glass guardrails. It covers the design, sizing and installation of glass guardrails in much greater detail. We’ve also published a new practical guide answering the ten most frequently asked questions about guardrails. It’s a good starting point for anyone looking for a quick answer to a specific question. You can find all this information on our website, buildwise.be. Search for guardrails in our assistant to find the campaign and its related publications. You can also use Tooli, our AI platform for the construction industry, which incorporates technical knowledge from Buildwise publications.
Closing the podcast
Björn Crul That’s all clear. Joeri, thank you very much for speaking with us.
Joeri Luckermans Yes, thank you.
Björn Crul That’s all for this podcast, produced in collaboration with Buildwise. Thank you for listening, and see you next time.