Om de ondergrondse parking droog te zetten, besloot G. Smeyers dertien bemalingsbronnen te boren en in bedrijf te stellen.
Om de ondergrondse parking droog te zetten, besloot G. Smeyers dertien bemalingsbronnen te boren en in bedrijf te stellen.

Resisterra is delivering one of the largest urban development projects in Flanders in the centre of Leuven.

Where the nursing school once stood, a cluster of three apartment buildings is taking shape. They are being built around a large courtyard garden, with a spacious underground car park below. G. Smeyers carried out the dewatering and recharge works.  

The Hertogensite is located between Brusselsestraat, Kapucijnenvoer, Minderbroedersstraat and the Dijle. To build the 90×67-metre underground car park, the groundwater level must be lowered from 1 to 9 metres below ground level. “It is no straightforward task, as the subsoil consists of a settlement-prone, peat-bearing clay layer about 6 metres thick,” says René Lambrechts, director of G. Smeyers. “Below that are several highly permeable layers, which
are sealed off by an alluvial gravel layer. A specialist consultancy calculated that dewatering using deep wells was required, within a 17.5-metre-deep groundwater cut-off wall. In addition, recharge was needed into the highly permeable alluvial gravel layer outside the excavation. Recharge wells were installed along the route of the vaulted Dijle. This meant the dewatering could be carried out under a Class 3 permit, as the discharged flow rate remains below 30,000 m³/year.” 

To build the 90×67-metre underground car park, the groundwater level must be lowered from 1 to 9 metres below ground level.

Commitment to results

Vandenbos, which is building the underground car park, asked G. Smeyers of Zonhoven to carry out the dewatering and recharge works. “It was the first time this contractor had engaged us,” says René Lambrechts. “And we did not let him down. Our expertise enabled us to optimise the dewatering study and reduce the cost. We also had no hesitation in undertaking a commitment to results, something other parties were unwilling to do. In the end, we decided to drill and commission thirteen
dewatering wells to keep the underground car park dry. Almost all the groundwater pumped out will be infiltrated back into the subsoil through nine recharge wells. Work is now under way and everything is progressing exactly to plan.”   

PROJECT DETAILS

Client Resisterra (Leuven)

Architect De Gregorio & Partners (Tongeren)

Main contractor(s) Vandenbos (Alken)

Een zakelijke vraag aan G. Smeyers N.V? Neem contact op

Bedrijven in dit verhaal

Blijf dit volgen

Bij een nieuw verhaal krijg je een e-mail. Geen account nodig.

Wat je volgt
  • OnderwerpGeneral
  • BedrijfG. Smeyers N.V
Deel dit artikel

Volgen op Bouwen aan Vlaanderen

Volg

Bij een project of bedrijf krijg je een e-mail zodra er een nieuw verhaal over verschijnt, bij een thema of onderwerp één keer per week een overzicht. Geen account en geen wachtwoord: in elke mail staat een link naar wat je volgt.