Fire-resistant glazed window and door assemblies and acoustics
Text and images Fire! Doors & Projects

These days, glazed window and door assemblies are subject not only to specific fire-resistance requirements, but increasingly to acoustic requirements too. “It is important to distinguish between the infill, in this case fire-resistant glazing, and the frame, in this case the window or door frame,” stresses Danny Jonckheere, managing director of specialist company Fire! Doors & Projects.

“Because of its construction, which consists of a sandwich structure of glass and an intermediate layer of film or gel, fire-resistant glazing is inherently solid and offers excellent acoustic performance,” says Danny Jonckheere. “For an EI30 installation, acoustic performance under EN 140-3, expressed as Rw, starts at around 38(-2,-2) dB, while for EI120 applications it can reach 47(-2,-3) dB. Note that decibel values do not vary linearly but logarithmically, so a difference of just a few decibels is perceptible. This can be improved further by using a thermally insulating version, with or without a laminated outer pane. When installing glazing in a window or door frame, account must be taken of the reduction in performance caused by joints, for example around the door, and by connections to walls or ceilings. This reduction can be estimated, but the result is not precise. Only an on-site measurement can confirm the actual acoustic attenuation achieved.”

A range of acoustic options
Fire! Doors & Projects offers various options in this regard, with frames and doors that can provide different levels of acoustic performance. “Fixed windows such as Fireframe, or steel or aluminium versions, guarantee the best results,” says Danny Jonckheere. “Results are still excellent with steel or aluminium rebated doors. With double-action doors installed in a Fireframe, you need to allow for a loss of performance due to the continuous open joint, which is a few millimetres wide. The same applies to Fireslide sliding doors, although in both cases the results are quite good and the loss of acoustic resistance is relatively limited thanks to the minimal size of the joints. As with fire-resistant joinery, acoustic performance depends on correct installation. A poor connection to the surrounding masonry will have a negative effect on both acoustic performance and fire safety. Another important consideration is the possible decoupling of wall elements and floors, to prevent vibrations from being transmitted alongside or beneath the acoustic walls, as this too can result in poor on-site measurement results.”
Question about this story? Ask your question
Keep following this
Get an email when a new story is published. No account needed.
- SubjectAcoustics


















