“Hollow-core floor units can be used anywhere”

The range of hollow-core floor units is extensive. They are available in reinforced or prestressed concrete, in various thicknesses and widths, and in lengths of up to 20 metres.
A choice of different options makes it possible to find the ideal solution for every situation.
Hollow-core floor units contain voids to reduce the consumption of raw materials and their own weight. This also reduces the amount of reinforcement required, which has a positive effect on CO2 emissions. Despite their lower self-weight, the required level of acoustic comfort in apartments can be achieved by coordinating the surface mass of the hollow-core floor units, the concrete topping, the levelling layer and the walls. In apartments, a floating screed
on a vibration-damping layer is always necessary, even with solid concrete floors.

Hollow-core floor units are self-supporting. This saves a considerable amount of time and ensures a high level of safety during installation. Prestressed units do not need temporary propping. Long reinforced concrete units are best propped at mid-span while the concrete topping is poured, to limit deflection. In many cases, a concrete topping is not necessary and filling the joints is sufficient. Reinforced concrete floor units are always available for rapid delivery from stock. Prestressed hollow-core floor units are usually made to order.

A wide range of options can be incorporated into hollow-core floor units, including openings, projecting reinforcement, longitudinal slots, hammerhead slots, reduced end thickness and increased concrete cover. These options make it possible to use hollow-core floor units for any floor in any building, whatever the shape of the floor area, the material of the supporting structure, the required fire resistance and the environmental exposure class or classes. Providing all these options at the factory greatly reduces the risk of construction errors and saves the contractor valuable time on site.
Prestressed concrete hollow-core floor units are highly rigid, allowing for long spans and slender structures. This makes it possible to maximise the usable space in a building and makes the building easy to adapt. Buildings will be demolished less often and renovated more frequently.
The EPB regulations set, among other things, a maximum U-value for flat roofs, floors above crawl spaces and floors between two apartments. To meet this requirement, insulation must be incorporated into the floor. Most manufacturers can apply insulation to the underside of the floor units. A thermally insulating levelling layer can be used in floors between two apartments. Any additional heat loss at thermal bridges must be included in the calculations. The junctions between the ground floor or flat roof and the façades are critical areas. Some manufacturers can supply insulated floor units with a nibbed bearing, making it possible to create EPB-compliant building junctions and minimise thermal bridges.
Hollow-core floor units increase a building’s thermal mass and therefore improve thermal comfort in both summer and winter. Energy consumption can be drastically reduced by combining a geothermal system with radiant panels or underfloor heating and night-time ventilation.
Floor units with a smooth formwork finish on the underside can be finished quickly and inexpensively with paint or spray-applied plaster. This applies to all prestressed floor units. The underside of reinforced concrete floor units can also have a rough-cast, hammered, waffle or grooved finish, rather than a smooth formwork finish, to improve the bond with a traditional plaster layer.
More information is available at www.febefloor.be.