Sustainability at the heart of design and delivery
Text Tim JanssensImage Dieter Meyns

The Loop business park in Ghent has gained another remarkable office building. The new Farys headquarters combines carefully considered massing with a strong focus on sustainability and quality of use. The BREEAM Outstanding design comprises a compact combination of an expansive podium and a six-storey, Z-shaped upper section, translating a complex functional puzzle into a clear, coherent whole. It reflects the ambition not only to optimise the water company’s internal operations, but also to anticipate future standards and regulations, such as the new EU Taxonomy.
Anyone who knows Ghent will no doubt also know the Farys building on Stropstraat. Before long, however, the water company will move to Field 5 at The Loop, where it has had a new headquarters built that clearly responds to current and future standards for comfort and sustainability. Farys will also be able to centralise its operations there more than ever. “Renovating and extending the existing premises was also an option, but it threatened to become a complex undertaking. The decision to move to a new location was therefore made fairly quickly. As we had already delivered other office projects for Banimmo at The Loop, the connection was obvious,” says Dimitri Vermeire, project architect at ARCH & TECO.

Reconciling different parameters
The new Farys building has a floor area of 10,318 m². The podium accommodates two parking levels, logistics areas and a large laboratory. The Z-shaped upper section houses two office wings, connected by a central circulation area with internal terraces on every floor. At ground-floor level, this connects to an entrance pavilion and a courtyard with a water garden. “The layout study carried out at the time for Field 5 at The Loop was based on 18 x 18 metre modules in plan. That was an important design parameter, as was the urban planning requirement that the building’s footprint above deck level should not exceed 1,500 m², with a height limit of six storeys.
The Z-shaped configuration was developed in response to the spatial organisation, orientation, sunlight and shading,” explains Dimitri Vermeire.

Specific studies
One of the project’s key words was sustainability, in the broadest sense of the word. This was guided by the BREEAM Outstanding criteria and the new EU Taxonomy guidelines, with a particular focus on materials and the technologies used (BEO field, heat pumps, PV panels …). “This involved a great many specific studies,” says Dimitri Vermeire. “After extensive research, we opted for a combination of EPS insulation and brick slips for the solid sections of the façade. This proved to enable a significant reduction in material use and CO
2
-emissions, partly because it required fewer transport movements than full-size bricks,” explains Dimitri Vermeire. “Since the building is intended for Farys, we also paid close attention to rainwater management in collaboration with sustainability consultancy Sureal, with the aim of delivering a T100 project. In other words, the substantial rain garden will only overflow into the street during a severe downpour that, in principle, occurs once every hundred years. In addition, retention roofs with a relatively deep build-up and correspondingly high water storage capacity have been installed. A good example is the extensive green roof on level 1, which connects to the roof of the neighbouring building and can also serve as a roof garden and terrace, with direct access to the staff restaurant.”

Tight schedule
The shell construction of the new Farys complex was carried out by Algemene Bouw Maes, which, like ARCH & TECO, was very much on home ground. “The biggest challenge was the tight schedule, with the main bottleneck being the installation of a BEO field with 48 geothermal boreholes beneath the foundation slab, supplemented by several boreholes alongside the building. The geothermal boreholes were drilled after the screw piles. As a result, it took around five months to complete all the work up to and including the foundation slab,” says lead project manager Jonas Van Durme. “After that, things moved quickly: the basement was completed in two months and was ready by the end of January 2025. Just after the 2025 construction holiday, we were already at level +6. In short, the precast concrete structure of the upper section was built in just six months. The finishing work also went smoothly, although the ETICS system with brick slips could only be installed when the surface temperature was above 5 °C. As we were only able to start in August 2025, quite a few days between November and January were unsuitable. The façades therefore had to be completed in a very short time too. We succeeded, and the building has been fully finished since February.”

An added dimension
Algemene Bouw Maes also played its part in achieving the sustainability ambitions. “A battery pack was on site from start to finish, partly to manage power peaks and partly because we were only given a 63A site connection, which significantly limited the available electrical capacity. Temporary heating for the building was provided using biodiesel supplied by Cargill. This resulted in a considerable reduction in CO2 emissions and 30 % less particulate matter during the construction phase. The choice of materials was also carefully aligned with the environmental requirements. CEM III A concrete was specified for the cast-in-situ structures, but we went a step further and used CEM III B concrete for the foundation slab and the pile caps in the basement. The building already meets the European sustainability targets for 2050, which gave this remarkable project an added dimension. I am very proud of what we achieved as a site team and of the quality of the work we delivered,” concludes Jonas Van Durme. “Quite rightly, as the collaboration went very smoothly and the end result is impressive,” agrees Dimitri Vermeire. “It has turned out to be a beautiful building, and Farys, which is handling the fit-out itself, is very pleased too. That’s what it’s all about!”

TECHNICAL DETAILS
Client, Banimmo (Brussels)
Architect, ARCH & TECO (Ghent)
Main contractor(s), Algemene Bouw Maes (Ghent)
Precast concrete supplier, Megaton/Structo Prefab Systems (Ninove)
Electro Verbeke: Electrical engineering
For the electrical works on the Farys project, Algemene Bouw Maes called on Electro Verbeke. “This is a shell-plus building, which means that some of the technical installations were included in the construction works. We started with the high-voltage installation, installing a 1,600 kVA transformer to supply electricity to the entire building and 85 future EV charging points. We also installed several electrical distribution boards, including a main low-voltage board, a number of distribution boards in the basement, and one on each floor of the office wings in preparation for possible future letting. We also installed the fibre connection and cabling for Wi-Fi and cameras, access control, fire detection and intruder alarm systems. Finally, we installed a series of solar panels on the roof. In short, we took care of all the electrical engineering that could be installed at this stage, to a very tight schedule,” says project manager Nico Pattijn. “As a great many changes were made along the way and the process of applying for new electricity connections is no longer as straightforward as it used to be, getting everything done in less than a year was a very demanding task,” adds director Isabelle Verbeke. “Nevertheless, we managed to meet the target schedule, partly by regularly bringing in additional staff. Flexibility and adaptability were certainly called for. This was the second time we had the opportunity to work for Algemene Bouw Maes, after they previously engaged us for Ekopak’s new base in Deinze. As on that occasion, we can look back on a positive collaboration, so we would certainly be happy to work together again!”
Socotec: Inspection of the enclosed structure, building envelope and building services
To ensure that every aspect of the new Farys head office was right, both structurally and technically, the client, Banimmo, called on the inspection firm Socotec. This formed part of a package covering three buildings and was carried out in connection with the ten-year liability insurance. “The Farys project involved, on the one hand, an inspection of the enclosed structure, meaning the load-bearing structure designed by the structural engineering firm, and the building envelope, including the wind stability and watertightness of the façades, roofs and external joinery. On the other hand, we also inspected the building services,” explains technical director Isabelle Valaert. “By checking that everything is carried out in accordance with good practice and the applicable standards and guidelines, we minimise the risk of damage occurring later, such as water ingress or elements coming loose. This provides additional reassurance for the client, particularly in the case of bespoke designs or detailing where we have to reconcile all manner of different requirements. Fire safety and interior finishes are also among the areas covered by our extensive expertise.” Construction is becoming increasingly complex, so an independent inspection firm such as Socotec adds considerable value, consultant Elina Karanastasi also points out. “We provide project certainty throughout the entire construction process and beyond. We do this by identifying potential problems early and preventing them, thereby reducing the risk of damage and keeping the costs associated with defects under control. As we oversee a huge number of projects every year and have strong links with academia, we also act as a kind of knowledge centre. Drawing on our extensive experience and expertise, we can contribute proactively, help avoid common mistakes and identify so-called red flags at an early stage. This project once again showed us that our input is greatly appreciated, as the collaboration was very pleasant. Having worked together on several projects, we have built up a relationship of trust with Banimmo and the other construction partners involved. The bar is high, not only structurally and technically, but also aesthetically and economically, and that is just how we like it!”
Question about this story? Ask your question
Who worked on it
Hoofdkantoor Farys in Gent
- clientBanimmo
- architectARCH & TECO
- main contractorAlgemene Bouw Maes
- leverancier prefabbetonelementenMegaton/Structo Prefab Systems
- ElektrotechniekenElectro Verbeke
Keep following this
Get an email when a new story is published. No account needed.
- ProjectHoofdkantoor Farys
- SubjectConstruction projects
- CompanyBanimmo
- CompanyARCH & TECO
- CompanyAlgemene Bouw Maes
- CompanyMegaton/Structo Prefab Systems
- CompanyElectro Verbeke